Gas Chromatography CLGC-601 offers a broad temperature range of 7ºC to 420ºC for versatile analysis. It is equipped with thermal conductivity detector for high sensitivity and accurate detection. Integrated with advanced software to enable automated peak integration for precise results. Built with intuitive touchscreen and display to ensure seamless operation. Our Gas Chromatography supports multiple carrier gases for flexibility in diverse analytical needs.
| Temperature Range | 7ºC to 420ºC |
| Temperature Accuracy | ± 0.02ºC |
| Cooling Time | 350°C to 100°C ≤ 3 min 400°C to 50°C in 8-10 min at 25°C ambient |
| Programmed Temperature Range | 0.1℃ to 80℃/min |
| Program Ramps | 20 Ramps |
| FID Detection Time | ≤ 8×10-12 g/s (n-hexadecane) |
| FID Baseline Drift | ≤ 1.5×10-13 A/h |
| FID Baseline Noise | ≤ 3×10-14 A |
| FID Linearity | ≥ 106 |
| TCD Maximum Operating Temperature | 400ºC |
| TCD Temperature Accuracy | ± 0.1ºC |
| TCD Detector Sensitivity | ≥ 10000 mV × mL / mg (n-Hexadecane) |
| TCD Baseline Noise | ≤ 20 μv |
| TCD Baseline Drift | ≤ 100 μv/30 min |
| TCD Linear Dynamic Range | ≥ 104 |
| FPD Detection | ≤ 8×10‐13 g/s(P); ≤8×10‐11 g/s(S) |
| FPD Baseline Drift | ≤ 2×10‐11 A/30 min |
| FPD Baseline Noise | ≤ 5×10‐12 A |
| NPD Detection Limit | ≤ 5×10-12 g/s(N) (Azobenzene) ≤5×10-13 g/s (P) (Malathion) |
| ECD Detection Limit | ≤ 3×10-14 g/ml |
| ECD Baseline Drift | ≤ 100 μV/30 min |
| ECD Baseline Noise | ≤ 40μV |
| Internal Dimension | 284 × 280 × 241 mm |
| External Dimension | 340 × 345 × 281 mm |
Fast Analysis
Real-Time Monitoring
Dual Injector Operation
High-Resolution Separation
Hydrogen Sensor
Gas Chromatography CLGC-601 is ideal for environmental monitoring, petrochemical analysis, food safety, pharmaceutical research, forensic science, and industrial process control.
M6 Software
Split/Non-Split Capillary Injector × 1
Flame Ionization Detector × 1
Thermal Conductivity Detector × 1
Flame Photometric Detector × 1
Electron Capture Detector × 1
Nitrogen Phosphorus Detector × 1
Autosampler 22 places × 1
Autosampler 156 places × 1
Ask Our Experts
Frequently Asked Questions
Our Gas Chromatography offers a broad temperature range of 7ºC to 420ºC, enabling versatile analysis across various applications.
The system allows programmed temperature rates from 0.1°C to 80°C/min with up to 20 ramps, ideal for complex separations.
It supports multiple detectors, including: FID (Flame Ionization Detector), TCD (Thermal Conductivity Detector), FPD (Flame Photometric Detector), NPD (Nitrogen-Phosphorus Detector) and ECD (Electron Capture Detector).
Yes, it is integrated with advanced software for automated peak integration and precise quantitative results.
The system features an intuitive touchscreen display, providing seamless control and real-time visualization.
Yes, it supports multiple carrier gases, offering analytical flexibility across diverse sample types.
Our GC system includes an injector, carrier gas supply, column (in an oven), detector and a data acquisition system.
We include Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD), Electron Capture Detector (ECD), and Mass Spectrometer (GC-MS).
The carrier gas (commonly helium, hydrogen, or nitrogen) transports the vaporized sample through the column for separation.
Compounds are separated based on their boiling points and affinity to the stationary phase in the column; different compounds travel at different speeds, leading to separation.
Our GC run may range from a few minutes to an hour, depending on the complexity of the sample and resolution required.
Detector: FID, TCD, ECD, FPD, NPD
Oven Temperature Range: 4°C – 450°C (increment 1°C)