Gas Chromatography CLGC-602

Gas Chromatography CLGC-602

Gas Chromatography CLGC-602 delivers superior accuracy with multiple advanced detectors. Equipped with electronic gas path control system to optimize flow management for consistent performance. Integrated with automatic mechanism to enhance operational efficiency and seamless analysis. Designed with injection port for optimal analytical operation. Our Gas Chromatography features a high-capacity column oven for optimal separation.

Detector FID, TCD, ECD, FPD, NPD
Oven Temperature Range 4°C – 450°C (increment 1°C)
Max Heating Rate 80°C/min
Temperature Accuracy ±0.01°C
Gas Circuit Control Manual & Electronic (EPC/EFC)
EPC Precision 0.01mL/min or 0.01Kpa
EPC Working Mode Constant current, constant voltage, shunt mode
EPC Gas Compatibility N₂, H₂, Air, He, Ar
Max Detector Temperature 450°C
Cooling Time 260°C to 50°C in 6 minutes
Display 8-inch touch screen

Digital Display

Double Oven

Diverse Injection System

Automatic Sampler

Software Interface

Gas Chromatography CLGC-602 is widely used in environmental analysis, pharmaceuticals, food safety, and petrochemical industries for precise separation and identification of chemical compounds.

FID

ECD

NPD

Split/non split injection port

Packed column injection port

Auxiliary gas path

Chromatography Anti-control Workstation

Liquid Auto Sampler, 156 Vials

Liquid Auto Sampler, 19 Vials

Liquid Auto Sampler, 22 Vials

Automatic sampling valve

Automatic sampling valve: Auto, 6-way

Automatic sampling valve: Auto, 10-way

Five positions 3-way valve × 3

Valve box

Filling column 1/8in × 1m imported filler

Filling column 4mm × 3m imported filler

Filling column 1/8in × 2m imported filler

Column installation components

Fully automatic headspace sampler

High purity hydrogen generator

Low noise air pump

Ask Our Experts

Frequently Asked Questions

1: What types of detectors are supported by the CLGC-602?

Our GC system supports multiple advanced detectors including FID, TCD, ECD, FPD, and NPD, making it suitable for a wide range of analytical applications.

2: What is the temperature range of the column oven?

The oven operates within a range of 4°C to 450°C, with 1°C increments for precise thermal control.

3: How fast can the system heat up?

The oven supports a maximum heating rate of 80°C per minute, enabling rapid analysis.

4: What EPC working modes are available?

The EPC supports constant current, constant voltage, and shunt mode for adaptable flow regulation.

5: Does the system include automation features?

Yes, it is integrated with automatic mechanisms to enhance operational efficiency and analytical precision.

6: Is there a dedicated injection port?

Yes, our system includes a precision-designed injection port to ensure optimal sample delivery and analytical performance.

7: What are the key advantages of the CLGC-602?

Key benefits include high detection flexibility, exceptional temperature accuracy, electronic gas flow control, and a user-friendly touchscreen interface.

8: What are the main components of a GC system?

Our GC system includes an injector, carrier gas supply, column (in an oven), detector and a data acquisition system.

9: What types of detectors are used in GC?

We include Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD), Electron Capture Detector (ECD), and Mass Spectrometer (GC-MS).

10: What is the role of the carrier gas?

The carrier gas (commonly helium, hydrogen, or nitrogen) transports the vaporized sample through the column for separation.

11: How does separation occur in GC?

Compounds are separated based on their boiling points and affinity to the stationary phase in the column; different compounds travel at different speeds, leading to separation.

12: How long does a GC run take?

Our GC run may range from a few minutes to an hour, depending on the complexity of the sample and resolution required.

Temperature Range: 7ºC to 420ºC

Temperature Accuracy: ± 0.02ºC