Gas Chromatography CLGC-602 delivers superior accuracy with multiple advanced detectors. Equipped with electronic gas path control system to optimize flow management for consistent performance. Integrated with automatic mechanism to enhance operational efficiency and seamless analysis. Designed with injection port for optimal analytical operation. Our Gas Chromatography features a high-capacity column oven for optimal separation.
Detector | FID, TCD, ECD, FPD, NPD |
Oven Temperature Range | 4°C – 450°C (increment 1°C) |
Max Heating Rate | 80°C/min |
Temperature Accuracy | ±0.01°C |
Gas Circuit Control | Manual & Electronic (EPC/EFC) |
EPC Precision | 0.01mL/min or 0.01Kpa |
EPC Working Mode | Constant current, constant voltage, shunt mode |
EPC Gas Compatibility | N₂, H₂, Air, He, Ar |
Max Detector Temperature | 450°C |
Cooling Time | 260°C to 50°C in 6 minutes |
Display | 8-inch touch screen |
Digital Display
Double Oven
Diverse Injection System
Automatic Sampler
Software Interface
Gas Chromatography CLGC-602 is widely used in environmental analysis, pharmaceuticals, food safety, and petrochemical industries for precise separation and identification of chemical compounds.
FID
ECD
NPD
Split/non split injection port
Packed column injection port
Auxiliary gas path
Chromatography Anti-control Workstation
Liquid Auto Sampler, 156 Vials
Liquid Auto Sampler, 19 Vials
Liquid Auto Sampler, 22 Vials
Automatic sampling valve
Automatic sampling valve: Auto, 6-way
Automatic sampling valve: Auto, 10-way
Five positions 3-way valve × 3
Valve box
Filling column 1/8in × 1m imported filler
Filling column 4mm × 3m imported filler
Filling column 1/8in × 2m imported filler
Column installation components
Fully automatic headspace sampler
High purity hydrogen generator
Low noise air pump
Ask Our Experts
Frequently Asked Questions
Our GC system supports multiple advanced detectors including FID, TCD, ECD, FPD, and NPD, making it suitable for a wide range of analytical applications.
The oven operates within a range of 4°C to 450°C, with 1°C increments for precise thermal control.
The oven supports a maximum heating rate of 80°C per minute, enabling rapid analysis.
The EPC supports constant current, constant voltage, and shunt mode for adaptable flow regulation.
Yes, it is integrated with automatic mechanisms to enhance operational efficiency and analytical precision.
Yes, our system includes a precision-designed injection port to ensure optimal sample delivery and analytical performance.
Key benefits include high detection flexibility, exceptional temperature accuracy, electronic gas flow control, and a user-friendly touchscreen interface.
Our GC system includes an injector, carrier gas supply, column (in an oven), detector and a data acquisition system.
We include Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD), Electron Capture Detector (ECD), and Mass Spectrometer (GC-MS).
The carrier gas (commonly helium, hydrogen, or nitrogen) transports the vaporized sample through the column for separation.
Compounds are separated based on their boiling points and affinity to the stationary phase in the column; different compounds travel at different speeds, leading to separation.
Our GC run may range from a few minutes to an hour, depending on the complexity of the sample and resolution required.