Ion Chromatograph CLIC-604

Ion Chromatograph CLIC-604

Ion Chromatograph CLIC-604 offers an exceptional pump flow rate of 0.001 to 12.000 mL/min. It provides flow stability of < 0.2% to ensure consistent ion separation. Equipped with intuitive control interface with real-time monitoring and data processing. Integrated with suppressor protection system for extended lifespan and stability. Our Ion Chromatograph requires minimal maintenance, reducing downtime and operational costs.

Qualitative Repeatability ≤ 1%
Quantitative Repeatability ≤ 1%
Pump Flow Rate 0.001 to 12.000 mL/min
Pump Head Pressure 0 to 40 MPa
Flow Setting Error < 0.2%
Flow Stability < 0.2%
Pressure Accuracy 0.01 Mpa
Pressure Pulsation < 0.25%
Detector Baseline Noise ≤ 0.0005 μS/cm
Detector Baseline Drift ≤ 0.005 μS/cm per 30min
Detector Resolution 0.00238 nS/cm
Minimum Detectable Concentration (Cl): ≤ 0.0005ug/mL
(Li): ≤ 0.0002ug/mL
(NO₃⁻): ≤ 0.001μg/mL
(Na⁺): ≤ 0.001μg/mL
(Ca₂⁺): ≤ 0.005μg/mL
Conductivity Cell Volume ≤ 0.4μL
Conductivity Cell Detection Range 0 to 45000 μS/cm
Conductivity Cell Temperature Error ±0.01℃/hr
Conductivity Cell Temperature Resolution 0.01℃
Conductivity Cell Temperature Range 5℃ to 65℃
Conductivity Cell Compensation Range 0 to 3.0 %
Conductance Cell Stability 0.05℃
Conductivity Cell Voltage 15 M
Suppressor Current Source Range 0 to 500 mA, increment 0. 1mA
Suppressor Dead Volume 50 μL
Suppressor Inhibition Capacity 170 μeq/min
Suppressor Withstand Pressure 3 MPa
Column Oven Temperature Range RT +5℃ to 70℃
Column Oven Temperature Stability ≤ 0. 1℃
Column Oven Temperature Error 0.05 ℃
Column Oven Compatibility 250mm and 150mm columns
Ambient Temperature 10 to 40℃
Relative Humidity 20 to 85 %
Power Supply 220V, 50HZ
Mainframe Dimension 1390 × 590 × 432 mm
Pump Dimension 212 × 570 × 430 mm
ECG Dimension 212 × 570 × 430 mm
Detector Dimension 442 × 425 × 590 mm
Net Weight 115 Kg
Gross Weight 195 Kg

Conductivity Detector

Eluent Generator

High-Pressure Capability

Fast Analysis

User-Friendly Software 

Ion Chromatograph CLIC-604 is widely used in environmental analysis, food safety, pharmaceuticals, quality control and industries for the detection and analysis of anions and cations.

Ask Our Experts

Frequently Asked Questions

1: How stable is the flow rate during operation?

Our ion chromatograph provides a flow stability of less than 0.2%, ensuring consistent and precise ion separation.

2: How user-friendly is the system?

Our system features an intuitive control interface with real-time monitoring and data processing, making it easy to operate even for new users.

3: What columns are compatible with the CLIC-604?

The column oven supports both 150 mm and 250 mm columns and maintains a temperature range from RT +5? to 70? with stability ? 0.1?.

4: What types of ions can be detected?

It is capable of detecting a wide range of anions and cations with high sensitivity, making it suitable for a broad range of analytical applications.

5: Is the CLIC-604 suitable for laboratory environments?

Yes, it’s designed for stable operation in standard laboratory conditions and is built to handle varying ambient temperatures and humidity levels.

6: How does Ion Chromatography work?

IC separates ions based on their interaction with a charged stationary phase inside a column. The ions are eluted with a mobile phase and detected by a conductivity or UV detector.

7: What is a suppressor in IC and what does it do?

A suppressor reduces background conductivity from the eluent, enhancing the sensitivity and selectivity of the ion detection, especially in anion analysis.

8: What types of samples can be analyzed using IC?

IC is suitable for aqueous samples containing inorganic or organic ions, including water, beverages, plant extracts, industrial effluents, and pharmaceuticals.

9: Can Ion Chromatography detect trace-level ions?

Yes, IC can detect ions at ppm (parts per million) to ppb (parts per billion) levels, especially when using suppressors and advanced detectors.

10: What are the advantages of IC over other techniques?

Ion Chromatography offers high sensitivity, reproducibility, selectivity, and simultaneous detection of multiple ions in one run with minimal sample prep.

Cell Volume: ≤ 0.8 μL

Detection Range: 0 to 35000 μS/cm

Cell Volume: ≤ 0.8 μL

Detection Range: 0 to 45000 μS/cm

Cell Volume: ≤ 0.8 μL

Detection Range: 0 to 50000 μS/cm

Qualitative Repeatability: ≤0.05%

Quantitative Repeatability: ≤0.3%