Triple Quadrupole GCMS CLTQC-601 operates at an ambient temperature of 18 to 25 ℃. Utilizes triple quadrupole technology for enhanced signal detection. Simultaneous acquisition modes for comprehensive compound identification. Equipped with automated tuning and calibration for consistent performance. Our Triple Quadrupole GCMS offers high mass resolution to distinguish compounds with similar masses.
Working Ambient Temperature | 18 to 25 ℃ |
Working Humidity | 20 to 60% RH |
Pumping Speed | 65 m3/h |
Sample volume | 0.1 μl to 250 μl |
Sampling Accuracy | ± 0.01% |
Sampling precision | RSD < 0.5% |
Flow rate | 0 to 500 ml / min (N2), 0 to 1000 ml/min (He) |
Maximum flow rate | 10 ml / min |
Inlet temperature | 450 °C |
Temperature control accuracy | ± 0.1 ℃ |
Humidity | 20 to 60% RH |
Pressure range | 0 to 100 psi |
Pressure control accuracy | ± 0.001 Psi |
Heating rate | Up to 120 °C / min, typically 50 °C / min |
Cooling time | 6 minutes |
Pressure control mode | Programmable Electronic Air Circuit Control |
Auto sampler | Optional |
Mass Analyzer | Triple Quadrupole Mass Analyzer |
Mass number range | 5 to 1100 amu |
EI Ion source temperature | 150 °C to 350 °C |
GC-MS interface temperature | 50 to 400 °C |
Scan rate | Up to 20,000 amu/s |
Stability | < ± 0.1 amu / 24 hrs. |
EI source ionization energy | 10 eV to 300 eV |
Resolution | 0.4 to 2 amu (adjustable) |
Detector | Pulse Counting Detectors |
Sensitivity | MRM mode: 1µL of 100 fg /µL OFN, ≥ 15000:1 |
Vacuum | Mechanical Pump and Turbo Molecular Pump |
Fast Analysis
Advanced Ionization Technique
Selectivity
Robust Data Processing
Integrated Software
Triple Quadrupole GCMS CLTQC-601 is widely used in food safety, environmental analysis, forensics, and pharmaceuticals to detect and quantify trace-level contaminants, pesticides, pollutants, and drug metabolites with high sensitivity and accuracy.
Host machine for MS part × 1 set
Customized host × 1 set
MS accessory kit × 1 set
GC accessory kit × 1 set
Adjustable operating table × 1 set
Vacuum mechanical pump × 1 set
Voltage regulator × 1 set
Mechanical pump × 1 set
Adapter plug × 1 set
Three-core power cord × 1 stick
CD-50 capillary column × 1 stick
DB-17ms gas chromatographic column × 1 stick
VF-WAXms gas chromatography column × 1 stick
Tuning solvent (OFN) × 1 bottle
10 µL SGE syringe with 50 mm fixed tapered needle, OD 0.63 mm
EI source filament × 1
Fluorine rubber O-ring, 1.5 × 1.5 mm (10 pcs/pack)
Helium trap
Thermolite Plus ultra-low loss inlet septa, Ø11 mm, heat resistant up to 300°C (10 pcs/pack)
Vespel/graphite ferrule for 0.25 mm ID column (10 pcs/pack)
Vespel/graphite ferrule for 0.32 mm ID column (10 pcs/pack)
Splitless GC inlet liner for gas chromatography
Precision split GC liner, 4 × 6.3 × 78.5 mm (5 pcs/pack)
Stainless steel split plate for GC inlet, 0.8 mm ID hole, straight-line split, surface inertized, with double-sided Vespel sealing ring
Alumina powder, 99.998% purity, 5 to 6 µm particle size (100 g, A102005)
Hand-screwed nut module
Single-head heating rod for vacuum use, 60W, 48V, Ø0.371-inch, 1 inch length
Ceramic insulation ring
Ceramic gasket
EI source holder
Hand-tightened capillary column connector
Electron multiplier
Cylinder pressure reducing valve
Pump oil, 2.5 L/bottle
Inline clean filter
2mL sample bottle (100pcs/box)
2mL sample bottle cap and gasket (100pcs/box)
GC empty column upgrade package
In-column backflush MS upgrade package